What Are the Advantages of china water cooled air dryer suppliers?
Aug. 13, 2024
Buy Air Dryer at Good Price - JAGUAR
01.Your Compressor Won't Start
If you are looking for more details, kindly visit NAILI.
A compressor that is on its last legs may stop powering on and indicate that it's time for a new one. On the other hand, if your compressor is still in good shape, you may have one of several issues. There are several reasons a compressor may refuse to start, some of which are more detrimental than others. Don't forget to look for the obvious, such as an unplugged compressor, before getting into troubleshooting.
One reason for start-up issues could involve your circuit breaker. The compressor could have tripped it at some point during operation. Check out the breaker and the switch that links up to the compressor. If it's in the "off" position, you know it's been triggered. Turn it back on. If the issue persists, enlist a professional to determine whether the problem is electrical or with your compressor. Another electrical issue might be in the fuse box, where you should check for a blown fuse.
Another situation that could cause your compressor not to start is insufficient cut-in air pressure. Your cut-in pressure, which determines the pressure at which the compressor starts running, needs to be proportional to the air stored in the tank. If they don't match up, a compressor can fail to start. Changing the cut-in setting on the pressure switch can fix this issue.
02.Your Compressor Won't Stop
A compressor that just keeps running and never stops could have a faulty pressure switch or pressure release valve. It should stop running when the tank pressure reaches a cutoff point. A bad pressure release valve won't release the pressure, making the tank too pressurized for the motor to stop running. If the pressure switch is bad, it won't alert the internal controls that the pressure is at the right level, so they won't know when to shut off. In both instances, a replacement should fix the issue.
03.You Hear Odd Noises from the Compressor
If your compressor is making loud noises, like rattling or screeching, you could be dealing with a few different problems:
Electrical failure is one issue that often causes a rattling compressor.
Another possibility is that a component is loose and needs to be tightened or replaced.
The distributor motor could also be loose.
If any of these problems occur, you'll want to call in an expert right away to prevent irreparable damage to your air compressor. If the noises have been going on for a while and you encounter other issues, it may be time for a new air compressor.
04.You Have Circuit Breaker Problems
If your compressor continuously trips the circuit breaker, you could be due for a new compressor. It may be drawing too much energy. While you might be tempted to repeatedly turn the circuit back on and continue work as usual, don't do this. It won't fix the problem and could be hazardous since the breaker trips to prevent fires. Enlist a professional at this point to see if there is an electrical problem or if you need a new compressor or repair.
05.Your Compressor Shakes or Makes Ticking Noises
Often, a shaky compressor can spell trouble for your system. It can indicate that it is struggling to start or function. If you ignore it, you will likely damage your system further and push it beyond repair. Usually, this shaking and chattering mean that something is out of place that can damage expensive components and necessitate an entirely new compressor if not addressed. On the other hand, if you can catch it right away and enlist a professional, you may be able to fix the compressor and identify what component is causing problems. Don't continue to use a compressor that shakes and makes these ticking sounds.
06.Your System Blows Warm Air
The compressor needs to pump refrigerant through it to cool the air. If this doesn't happen, you'll get warm or hot air from the openings. If the condenser is working well, it may have to do with the refrigerant supply. See if any refrigerant leaks are present and enlist the help of an expert to identify if the issue is fixable. Refrigerant issues can come from plenty of different sources, some of which can damage your compressor and create other problems.
07.You Find Moisture in or Around Your System
Every compressor system has some amount of condensation, but it shouldn't be excessive. If you've got a small river flowing through your compressor, you're going to have all sorts of issues. Too much free water in the system can significantly hurt the quality of the air supply, the system's functioning and its lifespan. Water can introduce rust or contamination to the air as it pulls the material throughout the system. As water mixes with contaminants li
08.Your Compressor Lags During Use
If it feels like your rotary screw compressor stutters or struggles to keep up, you may have a problem with the pump itself. Since this is such an essential part of an air compressor's operation, issues here can be detrimental. Some of the reasons a pump might fail before its expected lifespan include:
Excessive moisture in the system, which can come from condensate buildup
Overheating
System shake
Residue from lubrication
Industrial Air Dryer for Compressor | China Manufacturers
Description
Working Principle
The industrial air dryer machine for a compressor is based on the principle of freezing and dehumidification, which forcedly cools down the compressed air containing a large amount of saturated water vapor. While maintaining the pressure of the compressed air basically unchanged, the temperature of the compressed air is reduced, so that a large amount of water vapor in the compressed air is reduced.
It is in a supersaturated state, and in the saturated state, the water vapor condenses into liquid water droplets, entraining dust, through the steam-water separator, the moisture and dust are separated and discharged through the automatic drain, so as to achieve the purpose of freezing and dehumidification.
Core Advantages
« Perfect heat exchange performance, saving cooling power consumption
Sollant industrial air dryer for compressor, the pre-cooling and evaporation system adopts aluminum plate-fin heat exchanger design, the heat exchange performance is far greater than the conventional shell and tube heat exchanger, and the limit temperature difference between the air inlet and outlet can reach 2, reducing the required cooling capacity can better ensure the treatment effect and reduce the energy consumption of the refrigeration dryer.
« Large heat exchange area, small airflow gap
The aluminum plate-fin heat exchanger is constructed by overlapping multiple corrugated fins and baffles. The fin spacing is very small and the number of layers is large, so the heat exchange area is large. The heat exchange has a compact structure, but the fins airflow gap between is very small.
« Stainless steel wire mesh filter separation
Most of the water separators of aluminum plate-fin heat exchangers use stainless steel wire mesh filtering and separation methods, which have the advantages of simple structure and high separation of steam and water.
« Efficient refrigeration accessories
Danfoss thermal expansion and hot gas bypass valve can achieve precise operation and durability of the refrigeration system. The expansion valve controls the injection of liquid refrigerant into the evaporator, protecting the compressor from the influence of liquid refrigerant.
« Perfect control and protection device
- Realize condenser fan control through temperature and pressure sensing
- Sensor failure alarm
- Pressure dew point is a too high or too low indication
- Refrigerant high-temperature protection can stop the compressor when the exhaust temperature is too high
- Automatic start and stop of evaporator ice block
Industrial Air Dryer Technical Parameters
Model
Volume Flow (Nm3/min)
Power
Power consumption(kW)
Refrigerant
Connection size
Dimensions L*W*H(MM)
Weight
SLT-7.5NF
1
1Φ/220/50HZ
0.4
R22
RC1
620*450*620
46
SLT-10NF
1.5
1Φ/220/50HZ
0.65
R22
RC1
850*450*620
51
SLT-15NF
2
1Φ/220/50HZ
0.65
R22
RC1
850*450*620
51
SLT-20NF
2.6
1Φ/220/50HZ
0.8
R22
RC1
700*450*740
60
SLT-25NF
3
1Φ/220/50HZ
0.8
R22
RC1
700*450*740
60
SLT-30NF
3.8
1Φ/220/50HZ
1
R22
RC½
850*530*780
81
SLT-40NF
5.1
1Φ/220/50HZ
1
R22
RC½
850*530*780
81
SLT-50NF
6.7
1Φ/220/50HZ
1.4
R22
RC½
900*530*820
90
SLT-60NF
8.1
1Φ/220/50HZ
1.4
R22
RC½
900*530*820
90
SLT-75NF
11
1Φ/220/50HZ
1.9
R22
RC2
*530*850
131
Are you interested in learning more about china water cooled air dryer suppliers? Contact us today to secure an expert consultation!
SLT-100NF
15
3Φ/380/50HZ
2.7
R22
RC½
*700*920
150
SLT-125NF
18
3Φ/380/50HZ
3
R22
RC½
*700*920
150
SLT-150NF
20
3Φ/380/50HZ
4.2
R22
DN80
*780*
220
SLT-180NF
25
3Φ/380/50HZ
4.2
R22
DN80
*780*
220
SLT-200NF
28
3Φ/380/50HZ
5
R22
DN80
**
350
SLT-250NF
32
3Φ/380/50HZ
5.7
R22
DN80
**
390
SLT-300NF
35
3Φ/380/50HZ
5.7
R22
DN80
**
390
SLT-350NF
40
3Φ/380/50HZ
6.8
R22
DN80
**
430
SLT-400NF
45
3Φ/380/50HZ
8.7
R22
DN100
**
550
SLT-450NF
50
3Φ/380/50HZ
8.7
R22
DN100
**
550
SLT-500NF
55
3Φ/380/50HZ
10.5
R22
DN125
**
600
SLT-550NF
60
3Φ/380/50HZ
10.5
R22
DN125
**
600
SLT-650NF
68
3Φ/380/50HZ
11
R22
DN125
**
720
SLT-750NF
80
3Φ/380/50HZ
12.7
R22
DN150
**
980
SLT-850NF
87
3Φ/380/50HZ
12.7
R22
DN150
**
SLT-NF
110
3Φ/380/50HZ
17
R22
DN150
**
Want more information on oil free compressor supplier? Feel free to contact us.
61
0
0
Comments