Sign in

User name:(required)

Password:(required)

Join Us

join us

Your Name:(required)

Your Email:(required)

Your Message :

0/2000

What Are the Advantages of china water cooled air dryer suppliers?

Author: Justin

Aug. 13, 2024

Buy Air Dryer at Good Price - JAGUAR

01.Your Compressor Won't Start

If you are looking for more details, kindly visit NAILI.

A compressor that is on its last legs may stop powering on and indicate that it's time for a new one. On the other hand, if your compressor is still in good shape, you may have one of several issues. There are several reasons a compressor may refuse to start, some of which are more detrimental than others. Don't forget to look for the obvious, such as an unplugged compressor, before getting into troubleshooting.
One reason for start-up issues could involve your circuit breaker. The compressor could have tripped it at some point during operation. Check out the breaker and the switch that links up to the compressor. If it's in the "off" position, you know it's been triggered. Turn it back on. If the issue persists, enlist a professional to determine whether the problem is electrical or with your compressor. Another electrical issue might be in the fuse box, where you should check for a blown fuse.
Another situation that could cause your compressor not to start is insufficient cut-in air pressure. Your cut-in pressure, which determines the pressure at which the compressor starts running, needs to be proportional to the air stored in the tank. If they don't match up, a compressor can fail to start. Changing the cut-in setting on the pressure switch can fix this issue.

02.Your Compressor Won't Stop

A compressor that just keeps running and never stops could have a faulty pressure switch or pressure release valve. It should stop running when the tank pressure reaches a cutoff point. A bad pressure release valve won't release the pressure, making the tank too pressurized for the motor to stop running. If the pressure switch is bad, it won't alert the internal controls that the pressure is at the right level, so they won't know when to shut off. In both instances, a replacement should fix the issue.

03.You Hear Odd Noises from the Compressor

If your compressor is making loud noises, like rattling or screeching, you could be dealing with a few different problems:
Electrical failure is one issue that often causes a rattling compressor.
Another possibility is that a component is loose and needs to be tightened or replaced.
The distributor motor could also be loose.
If any of these problems occur, you'll want to call in an expert right away to prevent irreparable damage to your air compressor. If the noises have been going on for a while and you encounter other issues, it may be time for a new air compressor.

04.You Have Circuit Breaker Problems

If your compressor continuously trips the circuit breaker, you could be due for a new compressor. It may be drawing too much energy. While you might be tempted to repeatedly turn the circuit back on and continue work as usual, don't do this. It won't fix the problem and could be hazardous since the breaker trips to prevent fires. Enlist a professional at this point to see if there is an electrical problem or if you need a new compressor or repair.

05.Your Compressor Shakes or Makes Ticking Noises

Often, a shaky compressor can spell trouble for your system. It can indicate that it is struggling to start or function. If you ignore it, you will likely damage your system further and push it beyond repair. Usually, this shaking and chattering mean that something is out of place that can damage expensive components and necessitate an entirely new compressor if not addressed. On the other hand, if you can catch it right away and enlist a professional, you may be able to fix the compressor and identify what component is causing problems. Don't continue to use a compressor that shakes and makes these ticking sounds.

06.Your System Blows Warm Air

The compressor needs to pump refrigerant through it to cool the air. If this doesn't happen, you'll get warm or hot air from the openings. If the condenser is working well, it may have to do with the refrigerant supply. See if any refrigerant leaks are present and enlist the help of an expert to identify if the issue is fixable. Refrigerant issues can come from plenty of different sources, some of which can damage your compressor and create other problems.

07.You Find Moisture in or Around Your System

Every compressor system has some amount of condensation, but it shouldn't be excessive. If you've got a small river flowing through your compressor, you're going to have all sorts of issues. Too much free water in the system can significantly hurt the quality of the air supply, the system's functioning and its lifespan. Water can introduce rust or contamination to the air as it pulls the material throughout the system. As water mixes with contaminants li

08.Your Compressor Lags During Use

If it feels like your rotary screw compressor stutters or struggles to keep up, you may have a problem with the pump itself. Since this is such an essential part of an air compressor's operation, issues here can be detrimental. Some of the reasons a pump might fail before its expected lifespan include:
Excessive moisture in the system, which can come from condensate buildup
Overheating
System shake
Residue from lubrication

Industrial Air Dryer for Compressor | China Manufacturers

Description

Working Principle

The industrial air dryer machine for a compressor is based on the principle of freezing and dehumidification, which forcedly cools down the compressed air containing a large amount of saturated water vapor. While maintaining the pressure of the compressed air basically unchanged, the temperature of the compressed air is reduced, so that a large amount of water vapor in the compressed air is reduced.

It is in a supersaturated state, and in the saturated state, the water vapor condenses into liquid water droplets, entraining dust, through the steam-water separator, the moisture and dust are separated and discharged through the automatic drain, so as to achieve the purpose of freezing and dehumidification.

 

Core Advantages

«       Perfect heat exchange performance, saving cooling power consumption

Sollant industrial air dryer for compressor, the pre-cooling and evaporation system adopts aluminum plate-fin heat exchanger design, the heat exchange performance is far greater than the conventional shell and tube heat exchanger, and the limit temperature difference between the air inlet and outlet can reach 2&#;, reducing the required cooling capacity can better ensure the treatment effect and reduce the energy consumption of the refrigeration dryer.

«       Large heat exchange area, small airflow gap

The aluminum plate-fin heat exchanger is constructed by overlapping multiple corrugated fins and baffles. The fin spacing is very small and the number of layers is large, so the heat exchange area is large. The heat exchange has a compact structure, but the fins airflow gap between is very small.

«       Stainless steel wire mesh filter separation

Most of the water separators of aluminum plate-fin heat exchangers use stainless steel wire mesh filtering and separation methods, which have the advantages of simple structure and high separation of steam and water.

«       Efficient refrigeration accessories

Danfoss thermal expansion and hot gas bypass valve can achieve precise operation and durability of the refrigeration system. The expansion valve controls the injection of liquid refrigerant into the evaporator, protecting the compressor from the influence of liquid refrigerant.

«       Perfect control and protection device

  • Realize condenser fan control through temperature and pressure sensing
  • Sensor failure alarm
  • Pressure dew point is a too high or too low indication
  • Refrigerant high-temperature protection can stop the compressor when the exhaust temperature is too high
  • Automatic start and stop of evaporator ice block

 

Industrial Air Dryer Technical Parameters

Model

Volume Flow (Nm3/min)

Power

Power consumption(kW)

Refrigerant

Connection size

Dimensions  L*W*H(MM)

Weight

SLT-7.5NF

1

1Φ/220/50HZ

0.4

R22

RC1&#;

620*450*620

46

SLT-10NF

1.5

1Φ/220/50HZ

0.65

R22

RC1&#;

850*450*620

51

SLT-15NF

2

1Φ/220/50HZ

0.65

R22

RC1&#;

850*450*620

51

SLT-20NF

2.6

1Φ/220/50HZ

0.8

R22

RC1&#;

700*450*740

60

SLT-25NF

3

1Φ/220/50HZ

0.8

R22

RC1&#;

700*450*740

60

SLT-30NF

3.8

1Φ/220/50HZ

1

R22

RC½&#;

850*530*780

81

SLT-40NF

5.1

1Φ/220/50HZ

1

R22

RC½&#;

850*530*780

81

SLT-50NF

6.7

1Φ/220/50HZ

1.4

R22

RC½&#;

900*530*820

90

SLT-60NF

8.1

1Φ/220/50HZ

1.4

R22

RC½&#;

900*530*820

90

SLT-75NF

11

1Φ/220/50HZ

1.9

R22

RC2&#;

*530*850

131

Are you interested in learning more about china water cooled air dryer suppliers? Contact us today to secure an expert consultation!

SLT-100NF

15

3Φ/380/50HZ

2.7

R22

RC½&#;

*700*920

150

SLT-125NF

18

3Φ/380/50HZ

3

R22

RC½&#;

*700*920

150

SLT-150NF

20

3Φ/380/50HZ

4.2

R22

DN80

*780*

220

SLT-180NF

25

3Φ/380/50HZ

4.2

R22

DN80

*780*

220

SLT-200NF

28

3Φ/380/50HZ

5

R22

DN80

**

350

SLT-250NF

32

3Φ/380/50HZ

5.7

R22

DN80

**

390

SLT-300NF

35

3Φ/380/50HZ

5.7

R22

DN80

**

390

SLT-350NF

40

3Φ/380/50HZ

6.8

R22

DN80

**

430

SLT-400NF

45

3Φ/380/50HZ

8.7

R22

DN100

**

550

SLT-450NF

50

3Φ/380/50HZ

8.7

R22

DN100

**

550

SLT-500NF

55

3Φ/380/50HZ

10.5

R22

DN125

**

600

SLT-550NF

60

3Φ/380/50HZ

10.5

R22

DN125

**

600

SLT-650NF

68

3Φ/380/50HZ

11

R22

DN125

**

720

SLT-750NF

80

3Φ/380/50HZ

12.7

R22

DN150

**

980

SLT-850NF

87

3Φ/380/50HZ

12.7

R22

DN150

**

SLT-NF

110

3Φ/380/50HZ

17

R22

DN150

**

Want more information on oil free compressor supplier? Feel free to contact us.

31

0

Comments

0/2000

All Comments (0)

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name:(required)

Your Email:(required)

Subject:

Your Message:(required)

0/2000