Sign in

User name:(required)

Password:(required)

Join Us

join us

Your Name:(required)

Your Email:(required)

Your Message :

0/2000

Comparison of commercial endoscopic surgical staplers

Author: Evelyn

Sep. 09, 2024

Comparison of commercial endoscopic surgical staplers

Introduction

In , Hungarian surgeon Humer Hultl and Hungarian surgical device designer Victor Fisher developed the first internal surgical stapler.1 Since their introduction, surgical staplers have continuously evolved and are one of the most widely used surgical instruments for tissue transection, resection and creation of anastomoses. The evolution of the modern stapler facilitated the development of minimally invasive surgery, particularly in thoracic and general surgery. For instance, stapling has become part of the standard of care in video-assisted thoracic surgery (VATS) to treat lung cancer.2 Stapling also makes the method of extracorporeal/intracorporeal anastomosis in laparoscopic surgery possible for gastric cancer patients with faster recovery and less pain compared with open surgery.3

With competitive price and timely delivery, Ezisurg sincerely hope to be your supplier and partner.

As the volume of minimally invasive surgery using staplers that grows throughout the world, it is important that medical device manufacturers continue to develop and then evaluate stapling surgery outcomes. Although today's surgical staplers are safe, efficient, and reliable, a potential risk still exists for staple-line failures, leading to complications, including leakage from staple lines, bleeding, and fistula formation.4&#;6 In addition to staple-line failures, other complications that have been reported as adverse events (AE) related to tissue stapling include tissue damage due to fragility, stapler rocking during stapling, stapler-tissue thickness mismatch and technical failure.7

While various designs of surgical staplers are available, most staplers bend the staples into a B configuration that aids in securing the tissue. During the stapler firing sequence, malformed staples can result if the unformed staples do not properly align with the anvil pocket. Various tissue characteristics including tissue thickness, tissue viscosity, and differing properties between layers of tissue (eg, cartilage and mucosa in bronchus) can cause malformed staples to occur due to the staple leg being dragged or deflected during firing. Selecting the appropriate cartridge for a given target firing based on tissue characteristics is also critical as a mismatch could compromise the integrity of the staple line. In addition, staple properties such as staple diameter, unformed height, bending characteristics and metal composition can affect the staple leg&#;s ability to overcome tissue variation.8 Malformed staples can also occur if the stapler is fired over clips or a similar obstruction or the device fails to release from tissue.9,10

The Echelon+ Stapler with Thunderbird reloads (TBGST, Figure 1) has an advanced anvil curvature as well as wide, tapered staple pockets that are designed to improve the capture and formation of staples when the stapler is fired. The powered firing of the Echelon+ TBGST stapler adapts to tissue thickness; when used on thicker tissue, the speed of stapler firing decreases ensuring compression is uniform throughout the staple line, and staple formation is optimal.11 The Gripping Surface Technology (GST) incorporated in the Thunderbird reloads, provides improved tissue manipulation while securely holding tissue during stapling to improve tissue approximation and seal strength.12&#;16 In addition, the TBGST reload has glass fiber technology in the sled and driver for enhanced strength which is designed to provide better staple formation.

Figure 1 The Echelon+ Stapler with Thunderbird reloads.

To simulate the challenging conditions that may occur in surgery, we present here the results of a series of comparative ex-vivo tests performed in a laboratory-based setting. Staple form quality on relatively thick porcine stomach, as well as fluid leak pressure in colon and air leak pressure in bronchus were evaluated. Staplers evaluated were the Echelon+ TBGST Stapler with Thunderbird Reloads, the Reach Anzhi stapler and the Fulbright Lunar stapler with their corresponding reloads. These three staplers represent the most prevalent China commercial devices in the category of single-use powered articulating endoscopic cutter staplers.

Methods

All tissue testing was performed on ex vivo samples sourced from a commercial food supplier, hence no internal review board was necessary. Devices evaluated were the Echelon&#;+ stapler with Thunderbird (TBGST) reloads (PSEE60A stapler, GCFLGB/GCFLGG reloads, Ethicon, Inc., Cincinnati, OH, USA), the Reach Anzhi stapler with reloads (IM60AM stapler with REC60BLU/REC60GRN reloads, Reach Surgical Co., Ltd, Tianjin, China), and the Fulbright Lunar stapler with reloads (FSAM60 stapler with FMCB60/FMCG60 reloads, Fulbright Medical Inc., Wuxi, Jiangsu, China). The number of firings for all staplers was similar at the left, right and straight articulation positions.

Staple Form in Stomach

Porcine stomach of thickness 3.0&#;3.3 mm, determined by applying an 8 g/mm2 pressure for 15 seconds prior to measurement,17 was stapled of the stapler using a green reload. The tissue was mounted on tongue depressors using cyanoacrylate glue during computed tomography (CT) scanning. The imaging system (X50 CT System, North Star Imaging, Rogers, MN) was operated at 70 kV, 170 µA, for 720 projections at an 11.9 µm focal spot size. The scanned image was reconstructed with efX-CT Computed Tomography Reconstruction and Visualization (North Star Imaging). Images were analyzed by Kinetic Vision Inc. (Cincinnati OH) to provide staple form quality (SFQ). SFQ is a 5-point grading scale (Figure 2), with a score of 1&#;2 considered well formed, and 3&#;5 considered malformed.18 Statistical comparisons were performed using Fisher&#;s exact test with α = 0.05.

Figure 2 Staple Form Quality categories. Scores of 1&#;2 were considered well-formed, whereas 3&#;5 were considered malformed.

Bronchus Leak Pressure

Porcine bronchus of thickness 3.0&#;3.3 mm, determined by applying an 8 g/mm2 pressure for 15 seconds prior to measurement, was stapled at one end of the stapler using a green reload. Air leak testing was performed using a custom system designed by Advint LLC (Reynoldsburg OH) based on a metering pump (Pulsatron, Pulsafeeder, Punta Gorda, Florida) to fill the anastomosis with air at a rate of pressure increase of approximately 60 mmHg per minute with incremental steps every 15 seconds. Data were censored at 250 mmHg. The leak onset pressure was recorded, and the proportion of leakers below 88 mmHg was tallied. This criterion was chosen based on 88 mmHg being the maximum exhalation pressure that the diaphragm and thoracic muscles have been observed to exert.19 Statistical comparison was performed via Student&#;s t-test for mean observed leak pressure and Fisher&#;s exact test for frequency of leak at a pressure less than 88 mmHg with α=0.05.

Colon Leak Pressure

Staple firings using blue reloads were performed longitudinally on porcine colon of a selected tissue thickness range (1.5 ± 0.2 mm). The proximal end of the staple line was attached to a barbed Luer lock fitting and securely tied with a suture. The distal end was sealed with a zip tie and any leak at the zip tie was ignored unless the leak rate affected the recorded pressure, in which case the specimen was discarded. A computer-controlled pressure ramp-up rate of 30 mmHg/minute was utilized with dyed room-temperature water. Fluid leaks were visually identified as originating from the staple line or the cut line. If a staple line leak occurred, testing was continued until there was a cut line leak. Statistical comparison was performed via Student&#;s t-test for mean observed leak pressure and Fisher&#;s exact test for frequency of leak at a pressure less than 30 mmHg with α=0.05.20

Results

In Staple Form Quality testing in 3.0&#;3.3 mm stomach with green loads (Table 1, Figure 3), Echelon+ TBGST produced 97% fewer malformed (Category 3 or higher) staples than Fulbright Lunar and 92% fewer malformed staples than Reach Anzhi (p < 0.001).

Table 1 Summary of Comparisons Between Staplers

Figure 3 Percentage of malformed staples by SFQ (Staple Form Quality) category for Echelon+ TBGST, Reach Anzhi and Fulbright Lunar staplers in gastric tissue.

For more information, please visit Endoscopic Linear Cutter Staplers.

In air leak testing in the bronchus with green reloads (Figure 4), Echelon+ TBGST had a similar mean air leak pressure to Fulbright Lunar (p = 0.187), and a 56% higher mean leak pressure than Reach Anzhi (p < 0.001). Both the Echelon+ TBGST and Fulbright Lunar had no leaking below the 88 mmHg criterion, while Reach Anzhi had a 22% rate of leaking below the criterion, significantly higher than Echelon+ TBGST (p = 0.011).

Figure 4 Boxplot of bronchus air leak pressures for Echelon+ TBGST, Reach Anzhi and Fulbright Lunar staplers. Dotted lines represent target minimum values of 88 mmHg. Circles represent individual points, whereas those with a cross show statistical outliers. An asterisk represents a significant difference versus Echelon+ TBGST.

In fluid leak testing in the colon with blue reloads (Figure 5), Echelon+ TBGST had a 102% higher median leak pressure than Fulbright Lunar (p < 0.001) and 107% higher leak pressure than Reach Anzhi (p < 0.001). For the percentage of samples leaking below the 30 mmHg criterion, Echelon+ TBGST had 71% fewer leaks than Fulbright Lunar, and 76% fewer leaks than Reach Anzhi (p < 0.001).

Figure 5 Boxplot of colon fluid leak pressures for Echelon+ TBGST, Reach Anzhi and Fulbright Lunar staplers. Dotted lines represent target minimum values of 30 mmHg. Circles represent individual points, whereas those with a cross show statistical outliers. Asterisks represent a significant difference versus Echelon+ TBGST.

Discussion

Surgical staplers are used universally in laparoscopic procedures and are known to be reliable and convenient. Even though surgical staplers have low failure rates overall, bleeding and leakage are the leading complications that can increase the occurrence of morbidities and mortalities in surgery. Tissue thickness has been adduced as a factor in the mechanical integrity of the staple line, which may be a contributing factor to staple-line bleeding and leakage.21 In order to optimize staple formation, matching staple height to tissue thickness is the most common challenge to be overcome. Gastric tissue thickness is highly associated with difficulty in proper staple formation and serosal laceration in sleeve gastrectomy.11 Besides the gastric wall, thick tissue also is present in rectum in gastrointestinal surgery.22 The most common clinical practice scenario is transection/resection of gastrointestinal (GI) tissue and creation of anastomosis in laparoscopic procedures. GI tissues are considered biphasic with solid and liquid components, which may affect the manner in which staples are formed.23

In thoracic surgery, lung parenchyma can be thick in wedge resection depending on the cutting extension,24 and torn visceral pleura can lead to bleeding and air leakage.25,26 Bronchial stapling is another challenge in lung resection procedures, with possible post-operative complications of bronchopleural fistula formation and bleeding.7 The bronchial outer diameter is correlated with the compressed thickness, which is negatively related to the air leak pressure.27 Currently, one-third of the lung resection procedures is down-staging tumors after neoadjuvant treatment, where inflammation and fibrosis may lead to edema and adhesion, adding another factor to consider in assessing tissue and placement of stapler.28 Challenges when stapling lung tissue include slippage between the stapler surface, cartilage pieces, and mucosal tissues during firing, which may lead to malformation of staples. Increased resistance of cartilage would further lead to the possibility of penetration inconsistency of both legs and failure to align to the anvil pockets. Minor and/or major stapling failure could cause intra-operative air leak and post-operative bronchopleural fistula.7

Commonly, the staple is formed into a &#;B&#; configuration. The critical step of staple formation occurs when the anvil and sleigh are pushing staples upward and simultaneously the anvil pockets are guiding the staples into the B-shape formation. The staples are designed to be inert and are generally regarded as benign; however, slippage between the stapler surface and tissue during firing may lead to malformation of the staple. Malformed staples and their consequences have been reported in the scientific literature.29,30 Malformed staples can potentially cause detrimental adverse effects during surgery or post-operatively. Complications of malformed staples may include bleeding or the reopening of an incision if the staple line is not complete or does not hold.8

Although the thickness of gastric wall varies in patients, the thickest part is on antrum, which follows the body and fundus in a gradient manner.17 Using a pre-compression period of 15 seconds, the strength of TBGST reloads along with enhanced glass fiber technology secure tissue firmly to provide optimum B-shape staple formation. We used Staple Form Quality (SFQ), a 5-point grading scale (Figure 2), to evaluate the B-shape formation of each staple. In our study, on gastric wall with compressed thickness in range 3.0&#;3.3 mm, Echelon+ TBGST produced the fewest malformed staples (0.6%), compared to Reach Anzhi (7.1%, p < 0.001) and Fulbright Lunar (18.6%, p < 0.001). TBGST staple design is intended to overcome resistance of thick or rigid tissue and provide good formation with minimal chance of staple leg displacement from the pockets. Selecting the correct staple height, and an effective stapler/reload design is critical in the effort to reduce leaks31 and bleeding.15 In addition, the Echelon+ TBGST stapler is designed to decrease the firing speed when it engages thick tissues and slows down due to dynamic firing technology. The slower speed helps to improve the capture and formation of staples leading to fewer malformed staples. Better staple formation may be responsible for the higher leak pressures/lower rates of leakage observed in both bronchial and colon tissues.

The Gripping Surface Technology (GST) in TBGST reloads is designed to minimize tissue creep, while compression force is being applied. Since the GST 60 stapler was approved by the FDA in and the GST 45 stapler in , GST has been added to several stapler reloads and used not only in GI tissues but also in general, thoracic, urologic and pediatric procedures on both non-vascular and vascular targeting tissues.32&#;35 The Echelon+ TBGST Stapler has an advanced anvil curvature as well as wide, tapered staple pockets that are designed to improve the capture and formation of staples when the stapler is fired. In addition to glass fiber technology, stapler design has continued to evolve with TBGST reloads which are designed to provide optimal staple formation even on thick tissue.

The benefit of the advanced design of the Echelon&#;+ stapler with Thunderbird reloads is more pronounced while stapling in thick and challenging tissues, such as stomach or bronchus. There are two key features of the new design. First, Thunderbird reloads have enhanced glass fiber technology in the sled and driver for enhanced strength which is designed to provide optimal B-shaped staple formation. Secondly, Echelon+ TBGST is designed to decrease the firing speed while engaging thick tissues. This dynamic firing helps to improve the tissue capture and optimize staple formation.

In our study, TBGST green reloads with a target stapling height of 2.0&#;3.3mm were applied for bronchial closure. The compressed thickness of porcine bronchus 3.0&#;3.3mm was up to the high limit of green reloads. TBGST green reloads showed sufficient safety and performance with 0.0% air leak at the 88 mm Hg criterion. In the comparison of onset colon fluid leak pressure, consistent with the result of SFQ testing, the fluid leak pressure for ECHELON+ stapler with TBGST reloads was significantly higher than that for Reach Anzhi and Fulbright Lunar, with significantly lower leak rates below the 30 mmHg criterion. This test mimics the methylene blue leak test to test colonic anastomotic leak intraoperatively,36 and may provide insight to clinical performance.

Limitations of the Study

Even though thick and rigid tissue, such as gastric wall, colon, and bronchus, were tested in this study, this is an ex vivo study within a controlled experimental environment. Because this is an ex vivo study, intra-operative and post-operative bleeding could not be evaluated based on the model. An in vivo study will be explored to further assess the preclinical performance of tested devices.

Conclusion

Over the last several decades significant stapler technology advancements have occurred. Recent advancements in Ethicon Echelon+ TBGST stapler and reload include gripping strength technology and enhanced tissue management during powered firing with glass fiber technology. The stapler and reload design augments the stabilization of tissue which has demonstrated a decrease in the number of staple-line interventions and resulted in fewer hemostatic complications compared to standard stapler cartridge reloads in sleeve gastrectomy procedures.12,14 The use of powered staplers has been associated with decreased hospital costs as well as improved clinical outcomes.37&#;39

Proper formation of each staple is the fundamental guarantee of staple-line integrity and therefore strength. The Echelon+ TBGST Stapler with Thunderbird reloads produced fewer malformed staples and had as high or higher leak pressures in bronchus and colon tissue compared to similar competitor stapling systems in benchtop analyses. Clinical studies are needed to confirm these results.

Laparoscopic Linear Staplers

Laparoscopic Linear Stapler



The laparoscopic linear stapler is a very useful device for tissue approximation. A staple is made available in various sizes and heights so that the surgeon can choose the one that provides appropriate homeostasis/tissue apposition without significant ischemia or tissue destruction. Dimensions of commonly available staple cartridges that are used to accommodate different tissue thicknesses for appropriate tissue management is shown in the image below.


   Color of staple cartridge used for different tissue thicknesses

 
 Endoanchor and tacker
 


   The jaw of a stapler
 
Laparoscopic surgical instruments are extremely variable and an increasing number of instruments are being designed for a specific application. Instruments are getting complex with greater functionality and freedom of movement. Such instruments reflect the trend towards the automation of the procedure. In the future, such developments ultimately will lead to full robotization.

 If the closed staple height is too high, then it may inadequately oppose the tissues and result in leakage, bleeding, and/or dehiscence. Conversely, if the staple height selected is too low, then ischemia, serosal shearing, or &#;cheese wiring&#; may result, potentially leading to leakage or frank necrosis. There are at least three staple heights for most linear staplers. Most modern laparoscopic staplers bend each staple into a B-shape staple form, which helps to secure the tissue in place. However, malformed staples can occur because staple leg bending depends on several tissue/stapler characteristics including tissue thickness, tissue viscosity, staple height, and other staple properties (thickness, bending characteristics, type of metal, etc). Staples are designed to form consistently, and staples that are not forming as intended should be investigated.  


Echelon Flex Endopath Staplers

The Echelon flex endo-path staplers designed to deliver reliable performance across a wide range of tissue types and thicknesses on a one-handed, easy to use platform. Enhanced system-wide compression aids in proper staple formation, which is necessary to achieve a leak-resistant and hemostatic staple line. Compression before firing gently exudes fluid from targeted tissue before firing.


 
  Endopath articulating endoscopic linear cutters

   Endopath articulating endoscopic linear stapler



     Endopath ETS compact-flex45 articulating endoscopic linear cutters


Tri-Staple

 

 Covedian Endo GIA articulating endoscopic linear stapler cartridge



 
 Covedian Endo GIA articulating endoscopic linear stapler Gun


Endo GIA articulating endoscopic linear stapler and Tri-Staple is Covedian product and it is designed to work in harmony with the natural properties of tissue to optimize performance before, during, and after stapling. With its stepped cartridge face, Tri-Staple technology delivers optimum tissue compression, optimizing the interaction between the tissue and staple. It has the following advantages:

&#;    Generates less stress on tissue during compression and clamping
&#;    Allows greater perfusion into the staple line
&#;    Provides superior performance in variable thicknesses

Tri-Staple&#; technology improves staple line strength, leak resistance, and hemostasis when compared to the universal reloads. No single stapler can address the wide range of tissue management issues surgeons face on a daily basis. The current review focused on bariatric, thoracic, and colorectal studies. It was shown that different types of tissues have different thicknesses and biomechanical properties that may require the use of staples of different heights or the use of a different type of stapler (linear versus curved versus circular) to construct a stable anastomosis. Each tissue type has its own challenges, and the pathology of the tissue must also be taken into account.
 

The laparoscopic linear stapler is a very useful device for tissue approximation. A staple is made available in various sizes and heights so that the surgeon can choose the one that provides appropriate homeostasis/tissue apposition without significant ischemia or tissue destruction. Dimensions of commonly available staple cartridges that are used to accommodate different tissue thicknesses for appropriate tissue management is shown in the image below.Color of staple cartridge used for different tissue thicknessesEndoanchor and tackerThe jaw of a staplerLaparoscopic surgical instruments are extremely variable and an increasing number of instruments are being designed for a specific application. Instruments are getting complex with greater functionality and freedom of movement. Such instruments reflect the trend towards the automation of the procedure. In the future, such developments ultimately will lead to full robotization.If the closed staple height is too high, then it may inadequately oppose the tissues and result in leakage, bleeding, and/or dehiscence. Conversely, if the staple height selected is too low, then ischemia, serosal shearing, or &#;cheese wiring&#; may result, potentially leading to leakage or frank necrosis. There are at least three staple heights for most linear staplers. Most modern laparoscopic staplers bend each staple into a B-shape staple form, which helps to secure the tissue in place. However, malformed staples can occur because staple leg bending depends on several tissue/stapler characteristics including tissue thickness, tissue viscosity, staple height, and other staple properties (thickness, bending characteristics, type of metal, etc). Staples are designed to form consistently, and staples that are not forming as intended should be investigated.The Echelon flex endo-path staplers designed to deliver reliable performance across a wide range of tissue types and thicknesses on a one-handed, easy to use platform. Enhanced system-wide compression aids in proper staple formation, which is necessary to achieve a leak-resistant and hemostatic staple line. Compression before firing gently exudes fluid from targeted tissue before firing.Endopath articulating endoscopic linear cuttersEndopath articulating endoscopic linear staplerEndopath ETS compact-flex45 articulating endoscopic linear cuttersCovedian Endo GIA articulating endoscopic linear stapler cartridgeCovedian Endo GIA articulating endoscopic linear stapler GunEndo GIA articulating endoscopic linear stapler and Tri-Staple is Covedian product and it is designed to work in harmony with the natural properties of tissue to optimize performance before, during, and after stapling. With its stepped cartridge face, Tri-Staple technology delivers optimum tissue compression, optimizing the interaction between the tissue and staple. It has the following advantages:&#; Generates less stress on tissue during compression and clamping&#; Allows greater perfusion into the staple line&#; Provides superior performance in variable thicknessesTri-Staple&#; technology improves staple line strength, leak resistance, and hemostasis when compared to the universal reloads. No single stapler can address the wide range of tissue management issues surgeons face on a daily basis. The current review focused on bariatric, thoracic, and colorectal studies. It was shown that different types of tissues have different thicknesses and biomechanical properties that may require the use of staples of different heights or the use of a different type of stapler (linear versus curved versus circular) to construct a stable anastomosis. Each tissue type has its own challenges, and the pathology of the tissue must also be taken into account.

Want more information on linear cutter stapler customer service? Feel free to contact us.

11

0

Comments

0/2000

All Comments (0)

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name:(required)

Your Email:(required)

Subject:

Your Message:(required)

0/2000